Table 5. SPCN Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
1011 9116 SPCN communication failure with
operator panel
1. Operator panel
Location: L1
2. System board
Location: P1
Firmware Error Codes
Attention: If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 52 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to MAP
410: Repair Checkout in
Diagnostic Information for Multiple Bus Systems
.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 6. Firmware Error Codes
Error Code Description Action/ Possible Failing FRU
2011 0xxx Power supply
2011 031y Power supply failure 1. Replace power supply “y”.
2. Check the ac power source.
2022 0000 RIO bus running slow 1. Notify support
2. Processor card, Location: P1-C1
3. System board, Location: P1 (See
note 3 on page 37.)
Chapter 5. Error Code to FRU Index
111