If you are installing:
v A two-position SCSI disk drive bay, continue with “Removing a Two-Position SCSI
Disk Drive Bay”.
v A six-position SCSI (SES) or SSA hot plug disk drive bay, go to “Removing
Six-Position SCSI (SES) or SSA Disk Drive Bays” on page 347.
Removing a Two-Position SCSI Disk Drive Bay
To remove a two-position SCSI disk drive bay, use the following procedure:
1. If you have not already done so, shut down the system as described in “Stopping
the System Unit” on page 306.
2. If you have not already done so, remove the front and right side covers as
described in “Removing the Covers” on page 301.
3. Remove the drives from the two-position disk drive bay, as described in “Removing
a Disk Drive from the Two-Position Disk Drive Bay” on page 360.
4. Remove the screws holding the two-position disk drive bay in the system.
5. Label and disconnect the SCSI cable connectors from the backplane.
6. Slide the disk drive bay cage out of the system as shown in the following diagram.
Chapter 9. Removal and Replacement Procedures 345